EasyManuals Logo

Raytheon Anschütz STD 22 Compact GYRO COMPASS Installation And Service Manual

Raytheon Anschütz STD 22 Compact GYRO COMPASS
237 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #166 background imageLoading...
Page #166 background image
Installation and Service manual
Compass STD 22
Compass STD 22 Compact
156
Edition: Sept. 13, 2005
3646/110 --233.DOC010302
Serial
No.
Comments, InformationIndications
12.22 Indicate tap voltage (direct encoder voltage)
Balancing voltage indication: approx. 512 (= approx. 5mV)
Switch B 37 (DIP switch)
12345678
OPEN
B38
23X
B39
1X
Button B39 hold down: display in degree
Button B39 released again: display in a
coded value (appr. 182 per degree)
12.23 Indicate program number and software version of the program for the
microprocessor on the sensor PCB.
Switch B 37 (DIP switch)
12345678
OPEN
B38
23X
B39
1X