Timer A
M30240 Group
Rev.1.00 Sep 24, 2003 Page 148 of 360
Figure 2.8: Set-up procedure for timer mode
Setting divide ratio
Can be set to 000016 to FFFF16
b7 b0
(b15) (b8)
b7 b0
Timer A0 register [Address 0387 16, 038616] TA0
Timer A1 register [Address 0389
16, 038816] TA1
Timer A2 register [Address 038B
16, 038A16] TA2
Timer A3 register [Address 038D
16, 038C16] TA3
Timer A4 register [Address 038F
16, 038E16] TA4
Start count
Setting count start flag
Count start flag [Address 0380 16]
TABSR
Timer A0 count start flag
Timer A1 count start flag
Timer A2 count start flag
Timer A3 count start flag
Timer A4 count start flag
b7 b0
Pulse output function select bit
0 : Pulse is not output (TA iOUT pin is a normal port pin)
Selecting timer mode and functions
Timer Ai mode register (i=0 to 4) [Address 0396 16 to 039A16]
TAiMR (i=0 to 4)
Selection of timer mode
b7 b0
00000
0 (Must always be “0” in timer mode)
Count source select bit
0 0 : f
1
0 1 : f8
1 0 : f32
1 1 : Reserved
b7 b6
Count source period
f(X
IN
) : 12MH
Z
b7
b6
Count
source
83.3ns
667ns
2.67
µs
00
01
1
0
f
1
f
8
f
32
Gate function select bit
0 0 :
0 1 :
b4 b3
Gate function not available (TAi IN
pin is a normal port pin)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Renesas M16C Series and is the answer not in the manual?

Renesas M16C Series Specifications

General IconGeneral
BrandRenesas
ModelM16C Series
CategoryComputer Hardware
LanguageEnglish

Related product manuals