Universal Serial Bus
M30240 Group
Rev.1.00 Sep 24, 2003 Page 323 of 360
Figure 3.36: Initializing USB Suspend interrupt (3)
Stop all Clocks
001
System Clock Control Register Address
CM1 0007
16
All clock stop control bit
0 : Clocks on
1 : All clocks off (stop mode)
Stop Mode
b7 b0
00
Note: After setting bit 3, bit 5 should be established after waiting one cycle of the Φ.
Continued from previous page
NOP
NOP
Set the Interrupt enable flag i = 1
NOP
NOP