RL78/F13, F14 CHAPTER 16 SERIAL INTERFACE IICA
R01UH0368EJ0210 Rev.2.10 1080
Dec 10, 2015
(ii) When WTIM0 = 1
1: IICS0 = 0110×010B
2: IICS0 = 0010×110B
3: IICS0 = 0010×100B
4: IICS0 = 0010××00B
5: IICS0 = 00000001B
Remark : Always generated
: Generated only when SPIE0 = 1
×: Don’t care
(6) Operation when arbitration loss occurs (no communication after arbitration loss)
When the device is used as a master in a multi-master system, read the MSTS0 bit each time interrupt request signal
INTIICA0 has occurred to check the arbitration result.
(a) When arbitration loss occurs during transmission of slave address data (when WTIM0 = 1)
1: IICS0 = 01000110B
2: IICS0 = 00000001B
Remark : Always generated
: Generated only when SPIE0 = 1
ST AD6 to AD0 R/W ACK D7 to D0 D7 to D0ACK ACK SP
3 4 5 2
1
ST AD6 to AD0 R/W ACK D7 to D0 D7 to D0ACK ACK SP
2