RL78/F13, F14 CHAPTER 17 LIN/UART MODULE (RLIN3)
R01UH0368EJ0210 Rev.2.10 1222
Dec 10, 2015
The aforementioned timeout time is a time greater than the TFRAME_MAX of LIN Specification Package
Revision 1.3 on classic selection, or the TFRAME_MAX of LIN Specification Package Revision 2.x on
enhanced selection.
[Response timeout]
Timeout time = (number of data bytes + 1) × 14 [Tbit]
4. Only indication in the SFER flag can be enabled or disabled; error detection cannot be enabled or disabled.
5. Checksum determination is performed after response frame reception is completed. If the result is determined
as an error, the successful reception flag is not set to 1.
Caution The error status is cleared when cleared by software or after transition to LIN reset mode.