5886
ROM Update
The setting of this SP allows or prohibits updating the ROM.
*0:YES, 1:NO
5907
Plug/Play Plug & Play Maker/Model Name
Selects the brand name and the production name for Windows Plug & Play. This information is
stored in the NVRAM. If the NVRAM is defective, these names should be registered again.
5915
MechCountDetect Mechanical Counter Detection
0: Not detected, 1: Detected, 2: Unknown
Confirms that the mechanical counter inside the inner cover is connected.
5930
Meter Charge
This SP operates a "meter click charge" that maintains a total counter for the PCU, fusing unit,
and other components. When this SP is switched on, the use of the PCU, for example, is not
monitored by the engine but the engine counter continues to operate.
5961
Finisher Stack Finisher Paper Stack to Shift Tray?
0: OFF, 1: ON
Selects whether or not all stapled copies are sent to Shift Tray 1 when the Two-Tray finisher is
installed.
5990
SP Print Mode SMC Print
In the SP mode, press Copy Window to move to the copy screen, select the paper size, then
press Start. Select A4/LT (Sideways) or larger to ensure that all the information prints. Press
SP Window to return to the SP mode, select the desired print, and press Execute.
001 All (Data List) All (Data List)
002 SP (Mode Data Li) SP (Mode Data List)
004 Logging Data Logging Data
005 Diagnostic Repor Diagnostic Report
006 Non-Default Non-Default (Prints only SPs set to values other than defaults.)
Service Program Mode Tables