Service Call Conditions
SM Appendix 3-9 M018/M019
Appendix:
Trouble-
Shooting
Guide
SC 3xx (Charge Error)
High voltage power output error
The measured voltage is not correct when the EGB measures each charge output
(charge, development, image transfer belt unit, and transfer unit).
300
Disconnected or defective high voltage harness
Defective high voltage power supply
Defective EGB
1. Check or replace the harnesses.
2. Replace the high voltage power supply board
3. Replace the EGB.
Black drum motor error
The LOCK signal error is detected when the EGB monitors the black drum motor
state. (This monitoring is done immediately after power-on, when the motor starts
rotating, and immediately after the motor stops.)
396
Disconnected or defective motor harness.
Motor slips due to excessive load
1. Check the harness from the black drum motor. Replace it if necessary.
Color drum motor error
The LOCK signal error is detected when the EGB monitors the color drum motor
state. (This monitoring is done immediately after power-on, when the motor starts
rotating, and immediately after the motor stops.)
397
Disconnected or defective motor harness.
Motor slips due to excessive load
1. Check the harness from the color drum motor. Replace it if necessary.
http://www.manuals4you.com

Table of Contents

Other manuals for Ricoh Aficio SP C232SF

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ricoh Aficio SP C232SF and is the answer not in the manual?

Ricoh Aficio SP C232SF Specifications

General IconGeneral
BrandRicoh
ModelAficio SP C232SF
CategoryAll in One Printer
LanguageEnglish

Related product manuals