Service Menu
SM Appendix 4-13 M018/M019
Appendix:
SP Mode
Tables
Fax Maintenance
RTN Rate
The machine checks the actual data
reconstruction errors and then transmits an RTN
depending on the decoding error rate that is set by
this setting (Number of lines containing an error
per page / Total number of lines per page).
[10%/ 15%]
V34 Modem
DFU
[Permitted (Default)/ Prohibited]
Comm Settings
V17 Modem
DFU
[Permitted (Default)/ Prohibited]
Equalizer
These selectors set the equalizer's training level to
be applied if training fails due to poor line
connection.
[Automatic (Default)/ 4 Points/ 16 Points]
Redialing
Resend when a communication error occurs.
[Disabled (Default)/ Not Disabled]
First TX Speed
Sets the first transmission speed choice, before
fallback.
[2400 Bps/ 4800 Bps/ 7200 Bps/ 9600 Bps
/ 12000 Bps/ 14400 Bps/ 16800 Bps/ 19200 Bps/
21600 Bps/ 24000 Bps/ 26400 Bps/ 28800 Bps/
31200 Bps/ 33600 Bps (Default)]
V34 Settings
Symbol Rate
This setting limits the transmission speed range in
V.34 mode by masking the desired symbol rate(s).
[Not Used (Default)/ 3429 Sym/Sec
/ 3200 Sym/Sec/ 3000 Sym/Sec
/ 2800 Sym/Sec/ 2400 Sym/Sec]
http://www.manuals4you.com

Table of Contents

Other manuals for Ricoh Aficio SP C232SF

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ricoh Aficio SP C232SF and is the answer not in the manual?

Ricoh Aficio SP C232SF Specifications

General IconGeneral
BrandRicoh
ModelAficio SP C232SF
CategoryAll in One Printer
LanguageEnglish

Related product manuals