EasyManua.ls Logo

Ricoh CH-C1 - RTB 173: Manual correction

Ricoh CH-C1
682 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Bulletin PAGE: 1/2
Model: CH-C1 Office/Pro
Date: 12-Jun-17
No.: RD135173
Subject: Manual correction: the table of SC360/ SC362
Prepared by: K. Hamada
From: 2nd Tech Service Sect., MFP/P Tech Service Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Product Safety
Other ( )
Tier 2
Service Manual Correction
HTML version: Top Page > Main Chapters>Troubleshooting > Service call 300- 398
> SC300 (Engine: Development)
PDF version: page 1062 and 1063 (MP C6502 series Field Service Manual)
Delete the description in bold in the table of SC360 and SC362.
SC No.
Level
Error Name/ Error Condition/ Major Cause/ Solution
SC360-01
D
TD sensor adjustment error (K)
SC360-02
D
TD sensor adjustment error (C)
SC360-03
D
TD sensor adjustment error (M)
SC360-04
D
TD sensor adjustment error (Y)
During TD sensor initialization, TD sensor output voltage(Vt) cannot be
adjusted to the target range (target value ±0.2V)
Details:
TD sensor initialization adjust the TD sensor control voltage(Vtcnt) in
order to adjust the TD sensor output voltage(Vt) to target value ±0.2V.
Adjustment flow:
1. Developer presence detection
2. Developer not detected.
OK: Proceeds to Vtcnt adjustment
NG:SC336-0X
3. TD sensor calibration (Fluctuate Vtcnt and measure Vt)
4. TD sensor calibration result judgment
OK: TD sensor calibration succeeded.
NG: SC360-0X
- TD sensor defective
- Loose connection
- Harness broken
- Developer is not new
- Replace the TD sensor
- Replace the development unit

Table of Contents