following process.
Operation Method of read-in Program
a. First of all, link x-Messenger with your PC through the optional way: RS232 cable, USB cable(need install
driver first), Ethernet connection.
b. Open application software eSmsConfig, set up a new document, then open computer com. Click option
“Configuration” under menu “Tools” with left button of the mouse, or click“ ”in toolbar.
c. Click option “transfer->PC->x-Messenger” under menu “Tools”; or click button “ ”in toolbar
d. Click button “ ” with left button of mouse, start update Program, downloading status shown as Fig.
7.10.14 display update Program course.
Fig. 7.10.14 downloading status
Attn: After the Program update, x-Messenger will run the Program automatically, need not restart.
Operation Method of Upload Program:
a. Click option “Transfer->x-Messenger->PC” under menu “Tools” with left button of mouse, or click
“ ”under toolbar.
b. Click button “ ” with left button of mouse, start upload Program, uploading status shown as Fig.
7.10.14 display upload Program course.
6.13 How to prevent your program from being copied/stolen?
For OEM users, they have extremely high requirement on program protection, so our “program password”
might not be able to 100% cater for their high demand in this aspect.
In order to absolutely prevent user’s intellectual works(program in the CPU) from being copied/stolen by
unexpected personnel, user might make good use of “Disable read program” feature, and upon such feature
being activated, no one including user himself/herself can read program from CPU ,in other words, “program
upload” would be permanently prohibited, surely, under such situation, copy machine(ELC-COPIER) can not
work either. However, new program can still be allowed to be downloaded into such CPU. Therefore, please
take good care of your program, and save it in a safe place as backup to avoid unnecessary trouble resulted
from your program losing.