7.4. Error messages
Display Description Cause of error / Troubleshooting
Err. 0
Internal data error
Technical service required:
The controller cannot be repaired on site and
must be sent to the manufacturer for repair.
Err. 1
Temperature increase too low despite
heating at full power:
Kiln does not heat or heats too slowly
The kiln temperature is not increasing
as required.
The kiln has been on full power for 15
minutes, but the temperature has not
increased by at least 2 °C.
Kiln door or lid not completely closed.
Defective door switch
Door switch needs to be adjusted.
Heating element circuit open
Heating elements too old
Electrical power phase failure
Contactor failure
Err. 2
Thermocouple or wiring for thermocouple
disconnected
Get thermocouple and wiring checked.
Replace thermocouple if necessary.
Err. 3
Thermocouple with reversed polarity
Kiln temperature apparently below -40 °C
This is an installation fault.
Get wiring checked.
Err. 4
Kiln cools down too slowly:
Kiln does not cool down or cools down
too slowly.
The kiln has been on zero power for 30
minutes, but the kiln temperature has
not fallen by at least 1 °C.
Contactor failure (contacts possibly welded)
Thermocouple disconnected or resistance too
high
Err. 5
Set kiln temperature exceeded:
Desired temperature
Overshoot allowed
Below 100 °C + 60 °C
More than 100 °C but less
than 200 °C
+ 50 °C
More than 200 °C but less
than 600 °C
+ 30 °C
More than 600 °C + 20 °C
The kiln temperature has exceeded the desired
temperature by a preset limit.
The cause of the over-temperature must be
determined.
The contactor is not working (contactor
hangs/replace contactor).
Err. 6
Maximum duration of firing process
exceeded
The duration of the firing process exceeds a
limit value set in the factory.
Notes on Error 6:
The error is disabled at the factory.
If you want to set a maximum firing time,
please contact ROHDE Service.
Err. 7
The maximum room temperature
exceeded
The internal temperature of the controller has
exceeded a factory-set limit value.
Factory-set to 50 °C.
Possible causes:
- Insufficient or faulty ventilation of the kiln
chamber
- Operating location too small
- Ventilation grille blocked
- Exhaust air flap not closed
- Controller mounted too close to the kiln