80 / 293 - EN -
10.3. Changing parameters
Step Display Description Remark
1
Switch off the control unit.
2
8.8.8.8.
Switch on the control system and
simultaneously press the j key.
2
F 1.0 0
Continue to hold down the j key.
3
tC.S
Hold down the j key until the type of
thermocouple set is shown on the main
display.
The thermocouple type is only displayed
and cannot be changed here. The
thermocouple is preconfigured at the
factory.
4
tC.S
Now release the j key.
5
P14-
The main display shows the first
configurable parameter.
6
P60-
By pressing the d and f keys, you
can select the parameter to be
configured.
7
0
With the g key, you can call up the set
value of the parameter to be configured.
8
1
By pressing the d and f keys, you
can change the value.
9
1
You can save the value with the j key.
10
The control system display will go dark
for 23 seconds, and the control
system will restart automatically.
11
20
After the restart, the control system is
ready for normal operation again.
The set value is now permanently saved
for the respective parameter.
11. Cleaning the control unit
11.1. General safety information
CAUTION
The control system and the kiln must not be cleaned with a water jet, water hose or high-
pressure cleaner.
Do not use water or compressed air for cleaning. The possible consequences are:
- Damage to components
- Impairment of functions
- Failure of the control system and kiln
Always clean the control unit and kiln dry.