Electrical Adjustment
Grp / No. Item Function Range Initial Note
27 Illuminance Model Data 2 Lamp (2)(3), Eco, Ye:Off 0 - 32767 646
-
30 Illuminance Factory Data 3 Lamp (1)(2)(3), Normal, Ye:Auto 0 - 32767 11250
31 Illuminance Factory Data 3 Lamp (1)(2)(3), Normal, Ye:Off 0 - 32767 9338
32 Illuminance Factory Data 3 Lamp (1)(2)(3), Eco, Ye:Auto 0 - 32767 8438
33 Illuminance Factory Data 3 Lamp (1)(2)(3), Eco, Ye:Off 0 - 32767 7003
34 Illuminance Model Data 3 Lamp (1)(2)(3), Normal, Ye:Auto 0 - 32767 1531
35 Illuminance Model Data 3 Lamp (1)(2)(3), Normal, Ye:Off 0 - 32767 1669
36 Illuminance Model Data 3 Lamp (1)(2)(3), Eco, Ye:Auto 0 - 32767 1093
37 Illuminance Model Data 3 Lamp (1)(2)(3), Eco, Ye:Off 0 - 32767 1221
-
40 Illuminance Factory Data 3 Lamp (1)(2)(4), Normal, Ye:Auto 0 - 32767 11250
41 Illuminance Factory Data 3 Lamp (1)(2)(4), Normal, Ye:Off 0 - 32767 9338
42 Illuminance Factory Data 3 Lamp (1)(2)(4), Eco, Ye:Auto 0 - 32767 8438
43 Illuminance Factory Data 3 Lamp (1)(2)(4), Eco, Ye:Off 0 - 32767 7003
44 Illuminance Model Data 3 Lamp (1)(2)(4), Normal, Ye:Auto 0 - 32767 1404
45 Illuminance Model Data 3 Lamp (1)(2)(4), Normal, Ye:Off 0 - 32767 1542
46 Illuminance Model Data 3 Lamp (1)(2)(4), Eco, Ye:Auto 0 - 32767 998
47 Illuminance Model Data 3 Lamp (1)(2)(4), Eco, Ye:Off 0 - 32767 1116
-
50 Illuminance Factory Data 3 Lamp (1)(3)(4), Normal, Ye:Auto 0 - 32767 11250
51 Illuminance Factory Data 3 Lamp (1)(3)(4), Normal, Ye:Off 0 - 32767 9338
52 Illuminance Factory Data 3 Lamp (1)(3)(4), Eco, Ye:Auto 0 - 32767 8438
53 Illuminance Factory Data 3 Lamp (1)(3)(4), Eco, Ye:Off 0 - 32767 7003
54 Illuminance Model Data 3 Lamp (1)(3)(4), Normal, Ye:Auto 0 - 32767 1470
55 Illuminance Model Data 3 Lamp (1)(3)(4), Normal, Ye:Off 0 - 32767 1542
56 Illuminance Model Data 3 Lamp (1)(3)(4), Eco, Ye:Auto 0 - 32767 1056
57 Illuminance Model Data 3 Lamp (1)(3)(4), Eco, Ye:Off 0 - 32767 1127
60 Illuminance Factory Data 3 Lamp (1)(3)(4), Normal, Ye:Auto 0 - 32767 11250
61 Illuminance Factory Data 3 Lamp (1)(3)(4), Normal, Ye:Off 0 - 32767 9338
62 Illuminance Factory Data 3 Lamp (1)(3)(4), Eco, Ye:Auto 0 - 32767 8438
63 Illuminance Factory Data 3 Lamp (1)(3)(4), Eco, Ye:Off 0 - 32767 7003
64 Illuminance Model Data 3 Lamp (1)(3)(4), Normal, Ye:Auto 0 - 32767 1127
65 Illuminance Model Data 3 Lamp (1)(3)(4), Normal, Ye:Off 0 - 32767 1183
66 Illuminance Model Data 3 Lamp (1)(3)(4), Eco, Ye:Auto 0 - 32767 812
67 Illuminance Model Data 3 Lamp (1)(3)(4), Eco, Ye:Off 0 - 32767 871
240 Flow Calibration
0 Flow Calibration Exe
Flow Sensor Offset Calibration Start calibration when the value is
set to 1.
0 - 1 0
1 Flow Calibration Error Log
Log of Calibration Error (Read only)
255: Not Calibration
0: No Error
10: 1st Calibration Not Stable Airflow
11: 1st Calibration Out of Range
20: 2nd Not Stable Airflow
21: 2nd Out of Range
100: 10th Calibration Not Stable Airflow
101: 10th Calibration Out of Range
- 255
2 Clog Check Enable Filter Clogged Detection by Flow Sensor (0: Disable, 1: Enable) 0 - 1 Initial: 0 / Shipping: 1
3 Air Inlet Check Enable Intake Vent Error Check (0: Disable, 1: Enable) 0 - 1 Initial: 0 / Shipping: 1
5 Clog Auto Cooling Enable Cooling on Clog (0: Disable, 1: Enable) 0 - 1 1
6 Scroll Fail Auto Cooling Enable Cooling on Scroll error (0: Disable, 1: Enable) 0 - 1 1
8 Filter Counter Remainng Enable Filter Counter Remainning Function (0: Disable, 1: Enable) 0 - 1 1
9 Auto Cleaning Timer Enable Auto Cleaning Timer Function (0: Disable, 1: Enable) 0 - 1 1
10 Force Cleaning Rev Interval Force Cleaning Timer (0: Disable, 1 - 999 hurs) 0 - 999 0
11 Home Position Check Enable Drive unit Position Detection (0: Disable, 1: Enable) 0 - 1 1
12 Retry Cleaning Enable Retry Control (0: Disable, 1: Enable) 0 - 1 1
13 Filter Stanbdard Limit Filter life 0 - 255 120
14 Filter Max Limit Filter Limit 0 - 255 200
15 AMC Scroll Times Cleaning SCroll Times (read only) 0 -
16 AMC SCRoll Times Reset Reset Times of Cleaning Scroll 0 - 10 0
241 Flow Ideal Data (Value will be set after calibration)
0 Flow Ideal Data 1 Flow Sensor Theory Value No.1 Corresponding to Fan Volt No.1 0 - 1023 450
1 Flow Ideal Data 2 Flow Sensor Theory Value No.2 Corresponding to Fan Volt No.2 0 - 1023 530
2 Flow Ideal Data 3 Flow Sensor Theory Value No.3 Corresponding to Fan Volt No.3 0 - 1023 580
3 Flow Ideal Data 4 Flow Sensor Theory Value No.4 Corresponding to Fan Volt No.4 0 - 1023 615
4 Flow Ideal Data 5 Flow Sensor Theory Value No.5 Corresponding to Fan Volt No.5 0 - 1023 630
5 Flow Ideal Data 6 Flow Sensor Theory Value No.6 Corresponding to Fan Volt No.6 0 - 1023 1023
6 Flow Ideal Data 7 Flow Sensor Theory Value No.7 Corresponding to Fan Volt No.7 0 - 1023 1023

Table of Contents

Other manuals for Sanyo PLC-HF15000L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sanyo PLC-HF15000L and is the answer not in the manual?

Sanyo PLC-HF15000L Specifications

General IconGeneral
BrandSanyo
ModelPLC-HF15000L
CategoryProjector
LanguageEnglish

Related product manuals