MPS4232
Section 3: Operation
FUNCTION BYTES
DATA
TYPE
DESCRIPTION
Packet Type 2 Integer 0202

Mulple MPS units are stopped scanning by connecng
to one MPS and issuing a MSTOP command. This device
becomes the master and reissues a mulcast STOP
command. See the table below for the stop packet format.
All devices that are set up to listen to this mulcast address
will respond to the STOP command.

FUNCTION BYTES
DATA
TYPE
DESCRIPTION
Packet Type 2 Integer 0303

The user may connect to one MPS4200 and issue a MFIND
command. This command will return a list of all devices
that are part of the mulcast cluster. The MFIND command
uses the Discovery Packet described below.

FUNCTION BYTES
DATA
TYPE
DESCRIPTION
Packet Type 2 Integer 0101