PCR Accuracy Maximum
PCR_AC jitter (ns):
The maximum allowed PCR jitter for PCR_AC measurements. Default:
500 ns
PCR Accuracy Maximum
PCR_OJ jitter (ns):
The maximum allowed PCR jitter for PCR_OJ measurements.
PCR_OJ measurement does not apply to IP streams. Default: 500 ns
PTS: Enable or disable alarming of Presentation Time Stamp errors
PTS Maximum
interval (ms):
The maximum allowed interval between the reception of two PTS
values. Default: 700 ms
CAT: Enable or disable alarming of Conditional Access Table errors
CAT Maximum
interval (ms):
The maximum allowed section repetition interval for the CAT table.
Default: 500 ms
ETR Thresholds Priority 3:
NIT:
Enable or disable alarming of Network Information Table errors. Only
relevant when DVB mode is selected.
NIT Maximum
interval Actual (ms):
The maximum allowed section repetition interval for the NIT Actual table.
Default: 10 s
NIT Maximum
interval Other (ms):
The maximum allowed section repetition interval for the NIT Other table.
Default: 10 s
NIT Require
network id:
If enabled the probe will require that the network ID found in the NIT
matches the configured value. Default: Disabled
NIT Require
orig. netw. id:
If enabled the probe will require that the original network ID found in the
NIT matches the configured value. Default: Disabled
NIT Min.
num. transport streams:
The minimum number of transport streams that must be present in the
NIT. Set to 0 to disable this check. Default: 0
NIT Cable
descriptor (DVB-C):
If set to ‘Required’ an alarm will be generated if a DVB-C Cable descriptor
is not present in the NIT for the monitored frequency. Similarly if set to
‘Not allowed’, an alarm will be generated if the DVB-C Cable descriptor
is present. Default: Optional
NIT Cable
descriptor (DVB-C2):
If set to ‘Required’ an alarm will be generated if a DVB-C2 Cable de-
scriptor is not present in the NIT for the monitored frequency. Similarly
if set to ‘Not allowed’, an alarm will be generated if the DVB-C2 Cable
descriptor is present. Default: Optional
156 VB2xx GigE User’s Manual version 5.4

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sencore VB200-DC and is the answer not in the manual?

Sencore VB200-DC Specifications

General IconGeneral
BrandSencore
ModelVB200-DC
CategoryNetwork Hardware
LanguageEnglish

Related product manuals