Deleting a PID threshold template is done by highlighting the threshold template that should be removed
and clicking
Delete highlighted
. Note that if the deleted threshold template was assigned to a stream
being monitored, the new threshold for that stream will default to the predefined
Default
threshold
template.
The PID threshold template has the following settings:
Edit PID Threshold:
Name: The name of the PID threshold template
Description: Text field that should contain a meaningful description of the threshold template
PID Threshold Parameters:
Selection:
The user selects if the requirements should apply for a specific PID or for all
PIDs of a specified type. Note that the PID type detection depends on correct
PSI/SI/PSIP signaling.
PID:
The PID for which the specified requirements apply. If a PID type is selected
in the ‘Selection’ column, this field will update to read N/A when the
Apply
changes button is clicked.
Description: A text field describing the PID or PID type requirement
Require pres.:
If this field is checked an alarm will be raised provided that the specified PID
is not present in the transport stream. Note that this check is only available for
specified PIDs and not for PID types.
Monitor min BW:
An alarm is raised if the PID bandwidth goes below the specified minimum
bandwidth (bandwidth in kbit/s or Mbit/s) and monitoring is enabled.
Monitor max BW:
An alarm is raised if the maximum PID bandwidth specified is exceeded (band-
width in kbit/s or Mbit/s) and monitoring is enabled.
Req. language:
If the PID need to have a certain language code signaled in the language
descriptor it can be set here. An alarm will be raised if a wrong language is
signaled or if the language is not signaled.
VB2xx GigE User’s Manual version 5.4 165