Redundancy
Has FEC:
The stream carries COP3 (SMPTE 2022-5) Forward Error Correction. If enabled,
statistics about FEC drops and correctible errors will be reported for the stream.
First stream:
For a Seamless Protection Switching (SMPTE 2022-7) protected stream, select
the first of the two redundant RTP streams here. For other streams, (none) should
be selected.
Second stream: Select the second of the two redundant RTP streams here.
Seamless Protection Switching (SMPTE 2022-7) monitors the same stream transmitted twice. The probe
verifies that the two streams combined do not have packet loss and the jitter between the two streams.
When two multicast/unicast streams are selected, the probe will report errors report errors if the same
RTP packets are missing from both streams. Errors are also reported if the timing between the two
stream exceeds the threshold settings.
Seamless Protection Switching has been optimized for monitoring SDI over IP (SMPTE 2022-6) streams.
VB2xx GigE User’s Manual version 5.4 99