MX-3114N SIMULATION 6 – 65
44-43
Purpose
Data display
Function (Purpose)
Used to display the identification informa-
tion of the developing unit.
Section
Developing system
Operation/Procedure
The identification number and the identification signal level of the
developing unit are displayed.
* The developing unit is identified by the combination of items E, F, G, H and items I, J, K, and L.
44-62
Purpose
Setup/Adjustment
Function (Purpose)
Used to set the process control execution
conditions.
Section
Process
Operation/Procedure
This simulation allows collective change in the set contents of
SIM44-4 and SIM44-28.
A suitable one is selected among a number of options depending
on the condition.
1) Select an item to be set.
To change the image density in the high density area, select
PROCON TARGET.
To change the frequency of the process control operations,
select PROCON MODE.
Y
A DV_ADJ_CL_Y_L_DATA_1 DV bias correction data 1 in color printing (low speed) 0 - 5 0
B DV_ADJ_CL_Y_L_DATA_2 DV bias correction data 2 in color printing (low speed) 0 - 5 0
C DV_ADJ_CL_Y_L_DATA_3 DV bias correction data 3 in color printing (low speed) 0 - 5 0
D DV_ADJ_CL_Y_M_DATA_1 DV bias correction data 1 in color printing (middle speed) 0 - 5 0
E DV_ADJ_CL_Y_M_DATA_2 DV bias correction data 2 in color printing (middle speed) 0 - 5 0
F DV_ADJ_CL_Y_M_DATA_3 DV bias correction data 3 in color printing (middle speed) 0 - 5 0
G DV_ADJ_START_CL_Y_L_1 DV bias correction starting position data 1 in color printing (low speed) 1 - 12 4
H DV_ADJ_START_CL_Y_L_2 DV bias correction starting position data 2 in color printing (low speed) 1 - 12 3
I DV_ADJ_START_CL_Y_L_3 DV bias correction starting position data 3 in color printing (low speed) 1 - 12 1
J DV_ADJ_START_CL_Y_L_4 DV bias correction starting position data 4 in color printing (low speed) 1 - 12 1
K DV_ADJ_START_CL_Y_M_1 DV bias correction starting position data 1 in color printing (middle speed) 1 - 12 4
L DV_ADJ_START_CL_Y_M_2 DV bias correction starting position data 2 in color printing (middle speed) 1 - 12 3
M DV_ADJ_START_CL_Y_M_3 DV bias correction starting position data 3 in color printing (middle speed) 1 - 12 1
N DV_ADJ_START_CL_Y_M_4 DV bias correction starting position data 4 in color printing (middle speed) 1- 12 1
Button Item Display Content Setting
range
Default
value
Item/Display Content Display range NOTE
A DVCH KIND K K developing unit identification number 1 - 9 The model identification number of the developing unit which
is backed up in the EEPROM of the machine.
B DVCH KIND C C developing unit identification number 1 - 9
C DVCH KIND M M developing unit identification number 1 - 9
D DVCH KIND Y Y developing unit identification number 1 - 9
E DV_TYP_SEL_K K developing unit identification detection 0 - 1 0 = High (Open)
1 = Low (GND)
F DV_TYP_SEL_C C developing unit identification detection 0 - 1
G DV_TYP_SEL_M M developing unit identification detection 0 - 1
H DV_TYP_SEL_Y Y developing unit identification detection 0 - 1
I DVCH_AD_K K developing unit identification AD value 0 - 255 AD value of the developing unit identification voltage
J DVCH_AD_C C developing unit identification AD value 0 - 255
K DVCH_AD_M M developing unit identification AD value 0 - 255
L DVCH_AD_Y Y developing unit identification AD value 0 - 255
Display/Item Content
PROCON
TARGET
CL ID DOWN The densities of C, M, and Y decrease.
(The C/M/Y high density process control
target values decrease.)
CL ID UP The densities of C, M, and Y increase.
(The C/M/Y high density process control
target values increase.)
BK ID DOWN The density of K decreases. (The high
density process control target value
decreases.)
BK ID UP The density of K increases. (The high
density process control target value
increases.)
ALL ID DOWN The densities of C, M, Y and K decrease.
(The C/M/Y/K high density process
control target values decrease.)
ALL ID UP The densities of C, M, Y and K increase.
(The C/M/Y/K high density process
control target values increase.)
NORMAL The standard density of C, M, Y and K.
(The C/M/Y/K high density process
control target values are the standard
values.)