LEDs End cap with inte‐
gr
ated LED
Meaning
OSSD Field Diagnostics LEDs
1 2 3 4 5 6 7 8
O
R
ed
Ö
Ö
R
ed/
yellow
Ö
Yel‐
low
Ö
Yel‐
low
o o O Yel‐
low
o o o Ö Ö Red/yellow
Override required.
T
he protective field is
interrupted.
The topmost beam
was interrupted dur‐
ing partial blanking.
O
R
ed
Ö
Ö
R
ed/
yellow
o Ö
Yel‐
low
Ö
Yel‐
low
o O Yel‐
low
o o o Ö Ö Red/yellow
Override required.
T
he protective field is
interrupted.
At least one muting
sensor is engaged.
The muting condition
is not met.
O
R
ed
Ö
Ö
R
ed/
yellow
Ö
Yel‐
low
o o Ö
Yel‐
low
O Yel‐
low
o o o Ö Ö Red/yellow
Override required.
T
he protective field is
interrupted.
The total muting time
was exceeded.
O
R
ed
Ö
Ö
R
ed/
yellow
o o Ö
Yel‐
low
Ö
Yel‐
low
O Yel‐
low
o o o Ö Ö Red/yellow
Override required.
T
he protective field is
interrupted.
The concurrence
monitoring was
exceeded.
O
R
ed
Ö
Ö
Yel‐
low/r
ed
o Ö
Yel‐
low
o Ö
Yel‐
low
O Yel‐
low
o o o ÖÖ Yellow/red
Smart Box Detection
O
verride required.
The protective field
interruption is not
contiguous.
OR
The protective field
interruption does not
start at the lowest
light beam.
O
R
ed
Ö
Ö
Yel‐
low/r
ed
o o o Ö
Yel‐
low
O Yel‐
low
o o o ÖÖ Yellow/red
Smart Box Detection
O
verride required.
The object does not
have the required
minimum height.
O
R
ed
Ö
Ö
Yel‐
low/r
ed
o Ö
Yel‐
low
o o O Yel‐
low
o o o ÖÖ Yellow/red
Smart Box Detection
O
verride required.
The object is higher
than the allowed
maximum object
height.
O
R
ed
Ö
Ö
Yel‐
low/r
ed
o Ö
Yel‐
low
Ö
Yel‐
low
Ö
Yel‐
low
O Yel‐
low
o o o ÖÖ Yellow/red
Smart Box Detection
O
verride required.
The protective field
was interrupted dur‐
ing object entry
above the object
height detected later.
9 OPERATION
120
O P E R A T I N G I N S T R U C T I O N S | deTec4 8021645/1EB0/2022-04-28 | SICK