Configuring Smart Box Detection
OFF
uncoded
code 1
code 2
rev.conf.
ON
1 2 3 4
O F F
1 2 3 4
O F F
1 2 3 4
O F F
1
O N
2
A
B
C
D
1 2 3 4
O F F
Figure 62: DIP switch for Smart Box Detection on SP2 system plug
T
able 38: DIP switch and Smart Box Detection
DIP switch 3 (row C) Function
Off Smart Box Detection deactivated (delivery
s
tate)
On Smart Box Detection active
Note on configuration
b
Chec
k the parity after setting the DIP switch, see "Checking the parity", page 102.
7.11 Checking the parity
The parity must be checked after setting the DIP switches. The parity specifies whether
t
he sum of the DIP switches set to On is even or uneven.
Parity is only calculated for the DIP switches of rows A, B and C. DIP switches 1 and 2 of
row D are not included.
The parity is set using DIP switch 4 (row C).
7 C
ONFIGURATION
102
O P E R A T I N G I N S T R U C T I O N S | deTec4 8021645/1EB0/2022-04-28 | SICK
Subject to change without notice