LEDs End cap with inte‐
gr
ated LED
Meaning
OSSD Field Diagnostics LEDs
1 2 3 4 5 6 7 8
O
R
ed
Ö
Ö
Yel‐
low/r
ed
ÖÖ Yellow/red
Smart Box Detection
O
verride required.
An object has been
detected in the pro‐
tective field while the
OSSDs are in the
OFF state.
o LED of
f. Ö LED flashes. O LED illuminates. Empty cells mean that the LED lights up, flashes, or is off.
If front screen contamination increases in ongoing operation, the laser alignment aid
s
witches on or the alignment takes longer than 3 seconds, the receiver shows the
alignment quality again.
Further topics
•
"Indic
ation of the alignment quality", page 114
11.3.3 Fault indicators
Overview
In t
he event of a fault, the type of fault is indicated by the LED display on the sender or
receiver.
The information in the tables applies both for single devices and for every device in a
cascade.
When a device in a cascade shows a fault, the displays of the other devices in the
cascade must also be observed. The fault cause is only shown on the device in which it
occurs.
Sender
P
osition of the LEDs: see "Sender displays", page 21.
Table 46: Fault indication on the sender
LEDs Possible cause Troubleshooting
STATE Field
O Y
ellow o
Normal operation, no cable connec‐
t
ion between sender and receiver.
1)
–
O Y
ellow Ö Red
Fault in the voltage supply.
b
Check the voltage supply, see
"Technical data", page 140.
b
Switch the voltage supply off and
back on again.
b
If the fault persists, replace the
sender, see "Ordering informa‐
tion", page 150.
Ö Yellow Ö Red
The sender identified an internal
f
ault.
b
S
witch the voltage supply off and
back on again.
b
If the fault persists, replace the
sender, see "Ordering informa‐
tion", page 150.
O R
ed ÖÖ Yellow/green
Reset of the configuration to factory
se
ttings is activated.
For additional information: see "Fac‐
tory settings", page 93.
11 TROUBLESHOOTING
132
O P E R A T I N G I N S T R U C T I O N S | deTec4 8021645/1EB0/2022-04-28 | SICK
Subject to change without notice