EasyManua.ls Logo

SICK deTec4

SICK deTec4
176 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LEDs End cap with inte‐
gr
ated LED
Meaning
OSSD Field Diagnostics LEDs
1 2 3 4 5 6 7 8
O
R
ed
Ö
Ö
Yel‐
low/r
ed
o Ö
Yel‐
low
o Ö
Yel‐
low
O Yel‐
low
o o o ÖÖ Yellow/red
Smart Box Detection
O
verride required.
The protective field
interruption is not
contiguous.
OR
The protective field
interruption does not
start at the lowest
light beam.
O
R
ed
Ö
Ö
Yel‐
low/r
ed
o o o Ö
Yel‐
low
O Yel‐
low
o o o ÖÖ Yellow/red
Smart Box Detection
O
verride required.
The object does not
have the required
minimum height.
O
R
ed
Ö
Ö
Yel‐
low/r
ed
o Ö
Yel‐
low
o o O Yel‐
low
o o o ÖÖ Yellow/red
Smart Box Detection
O
verride required.
The object is higher
than the allowed
maximum object
height.
O
R
ed
Ö
Ö
Yel‐
low/r
ed
o Ö
Yel‐
low
Ö
Yel‐
low
Ö
Yel‐
low
O Yel‐
low
o o o ÖÖ Yellow/red
Smart Box Detection
O
verride required.
The protective field
was interrupted dur‐
ing object entry
above the object
height detected later.
O
R
ed
Ö
Ö
Yel‐
low/r
ed
Ö
Yel‐
low
o Ö
Yel‐
low
o O Yel‐
low
o o o ÖÖ Yellow/red
Smart Box Detection
O
verride required.
The object height
is above the object
height detected at
the beginning.
OR
The protective field
above the detected
object is interrupted.
O
R
ed
Ö
Ö
Yel‐
low/r
ed
Ö
Yel‐
low
Ö
Yel‐
low
o Ö
Yel‐
low
O Yel‐
low
o o o ÖÖ Yellow/red
Smart Box Detection
O
verride required.
The total time for
Smart Box Detection
has been exceeded.
The object is still in
the protective field.
O
R
ed
Ö
Ö
Yel‐
low/r
ed
Ö
Yel‐
low
Ö
Yel‐
low
Ö
Yel‐
low
Ö
Yel‐
low
O Yel‐
low
o o o ÖÖ Yellow/red
Smart Box Detection
O
verride required.
The protective field is
still interrupted after
the expected object
exit.
TROUBLESHOOTING 11
8021645/1EB0/2022-04-28 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4
131