LEDs End cap with inte‐
gr
ated LED
Meaning
OSSD Field Diagnostics LEDs
1 2 3 4 5 6 7 8
O
R
ed
O
Red
O Red
Its own protective
f
ield is interrupted.
The indicator is inde‐
pendent of the sta‐
tus of the other pro‐
tective fields.
OR
The override push‐
button has just been
actuated.
OR
The protective field is
clear.
The reset button has
just been actuated.
OR
An error has occur‐
red in Smart
Box Detection. The
device is not in
the Override required
state.
O
R
ed
Ö
Yel‐
low
Ö Yellow
The protective field is
c
lear.
Reset required.
Ö
Y
el‐
low
The reset pushbut‐
t
on is defective or is
being actuated con‐
tinuously. Check the
wiring of the reset
pushbutton.
O
R
ed
Ö
Yel‐
low
EDM warning: The
EDM in
put has no
signal. Check con‐
tactors and wiring.
Switch the voltage
supply off and back
on again.
O
Gr
een
O Y
el‐
low
O Yellow
Muting is currently
ac
tive. The protective
field is bypassed.
OR
Smart Box Detection
is configured. A valid
object is located in
the protective field.
OR
The device is in the
Override state.
O
Gr
een
O Y
el‐
low
O
White
O Yellow
Partial blanking is
c
urrently active. Only
the topmost beam is
active.
TROUBLESHOOTING 11
8021645/1EB0/2022-04-28 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4
129
Subject to change without notice

Table of Contents

Other manuals for SICK deTec4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK deTec4 and is the answer not in the manual?

SICK deTec4 Specifications

General IconGeneral
BrandSICK
ModeldeTec4
CategorySafety Equipment
LanguageEnglish

Related product manuals