Chapter 5
MSC800
8011540/14B8/2019-06-06 Operating instructions | SICK 51
Subject to change without notice
Electrical installation
MSC800-3600
Fig. 21: Terminals on the MSC800-3600 for mains voltage IN and supply voltage OUT
Connections for mains voltage IN on the MSC800-3600
Terminal Color Signal Function
-X100/1.1 Gray L Mains voltage AC 100 ... 264 V / 50 ... 60 Hz (phase)*
-X100/1.2
Gray
L
-X100/1.3
Gray
L
-X100/1.4 Blue N Mains voltage AC 100 ... 264 V / 50 ... 60 Hz (neutral
conductor)
-X100/1.5 Blue N
-X100/1.6
Green-yellow
PE
Protective conductor
-X100/1.7
Green-yellow
PE
* After removing the bridge between the gray terminals, the assignment also has three different phases
Tab. 22: MSC800-3600: -X100 terminal block pin assignment for mains voltage IN
Connections for supply voltage OUT 1 ... OUT 3 on the MSC800-3600
Terminal
set
Terminal Signal Function Protected by the
automatic circuit
breakers
KLS1
-X120/11
DC +24 V
Supply voltage OUT 1
(power supply unit modules 1)
–F111
-X120/13 DC +24 V –F113
-X120/15 DC +24 V –F115
-X120/12
GND
Ground 1
-X120/14
GND
-X120/16 GND
-X120/17 Shield Shield
-X120/18
Shield
-X120/19
Shield
Tab. 23 MSC800-3600: assignment of the -X120 terminal block, part 1 for
supply voltage OUT 1 on ICR890 (system 1)