EasyManuals Logo

Siemens SIMATIC ET 200SP System Manual

Siemens SIMATIC ET 200SP
320 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #133 background imageLoading...
Page #133 background image
Configuring
7.1 Configuring ET 200SP
Distributed I/O system
132 System Manual, 09/2019, A5E03576849-AJ
Requirements for configuration of the CPU
Table 7- 1 Requirement for installing the CPU
Configuration software
Requirements
Installation information
CPU 151xSP-1 PN:
STEP 7 (TIA Portal) as of V13 Update 3
PROFINET IO
PROFIBUS DP (optional): With
the communication module CM
DP
STEP 7 online help
CPU 151xSP F-1 PN:
STEP 7 (TIA Portal) as of V13 SP1
CPU 151xSP-1PN (as of FW version V1.8),
CPU 151xSP F-1 PN (as of FW version V1.8):
STEP 7 (TIA Portal) as of V13 SP1 Update 4
Requirements for configuration of the interface module
Table 7- 2 Requirement for installing the interface module
Configuration software
Requirements
Installation information
STEP 7 (TIA Portal) as of
V11 SP2*
PROFINET IO: As of Support Package HSP0024
STEP 7 online help
PROFINET IO: STEP 7
V5.5 SP4 HF1
or higher PROFINET DP:
STEP 7 V5.5 SP2 or higher
PROFINET IO: GSD file GSDML-Vx.y-siemens-
et200sp-"Date in format yyyymmdd".xml
(
http://support.automation.siemens.com/WW/view/en/
19698639/130000)
PROFIBUS DP: GSD file SI0xxxxx.gsx
(
http://support.automation.siemens.com/WW/view/en/
10805317/14280)
Software of third-party
manufacturer
Manufacturer documentation
* The TIA
Portal supports GSDML specification V2.25. The ET 200SP distributed I/O system is delivered with a GSD file
based on specification V2.3. The GSD file can be installed in the TIA Portal and used without restrictions.
Configuring a motor starter
You configure SIMATIC ET 200SP motor starters in exactly the same way as the I/O
modules of the ET 200SP distributed I/O system.
The GSD files can be used with STEP 7
V5.5 SP4 and higher, and TIA Portal V13 SP1 and higher.

Table of Contents

Other manuals for Siemens SIMATIC ET 200SP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC ET 200SP and is the answer not in the manual?

Siemens SIMATIC ET 200SP Specifications

General IconGeneral
System TypeDistributed I/O System
MountingDIN Rail
Communication ProtocolPROFINET, PROFIBUS
IP RatingIP20
CategoryI/O Systems
Supply Voltage24 V DC
ModularityYes
Hot SwappingYes
Storage Temperature-40°C to +70°C
Digital InputsYes
Digital OutputsYes
Analog InputsYes
Analog OutputsYes
Communication InterfacePROFINET, PROFIBUS
Number of ModulesUp to 64
Relative Humidity5 to 95% (non-condensing)
Operating Temperature-25°C to +60°C

Related product manuals