Basics of program execution
8.2 Asynchronous instructions
Distributed I/O system
154 System Manual, 09/2019, A5E03576849-AJ
Technology: maximum number of concurrently running jobs
Table 8- 9 Maximum number of concurrently running jobs for asynchronous instructions for technology. The instructions
for technology use a common pool of resources.
Technology
CPU 1510SP-1 PN
CPU 1510SP F-1 PN
CPU 1512SP-1 PN
CPU 1512SP F-1 PN
Motion Control
MC_Power
MC_Reset
MC_Home
MC_Halt
MC_MoveAbsolute
MC_MoveRelative
MC_MoveVelocity
MC_MoveJog
MC_GearIn
MC_MoveSuperimposed
MC_MeasuringInput
MC_MeasuringInputCyclic
MC_AbortMeasuringInput
MC_OutputCam
MC_CamTrack
MC_TorqueLimiting
300
Additional information
You can find additional information on block parameter assignment in the STEP 7 online
help.

Table of Contents

Other manuals for Siemens SIMATIC ET 200SP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC ET 200SP and is the answer not in the manual?

Siemens SIMATIC ET 200SP Specifications

General IconGeneral
System TypeDistributed I/O System
MountingDIN Rail
Communication ProtocolPROFINET, PROFIBUS
IP RatingIP20
CategoryI/O Systems
Supply Voltage24 V DC
ModularityYes
Hot SwappingYes
Storage Temperature-40°C to +70°C
Digital InputsYes
Digital OutputsYes
Analog InputsYes
Analog OutputsYes
Communication InterfacePROFINET, PROFIBUS
Number of ModulesUp to 64
Relative Humidity5 to 95% (non-condensing)