EasyManua.ls Logo

Siemens SIMATIC ET 200SP - Page 278

Siemens SIMATIC ET 200SP
320 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical specifications
14.2 Electromagnetic compatibility
Distributed I/O system
System Manual, 09/2019, A5E03576849-AJ
277
Table 14- 4 Sinusoidal disturbance variables with RF coupling
RF coupling in accordance with IEC 61000-4-6
Corresponds to degree
of severity
(10 kHz) 150 kHz to 80 MHz
3
10 V
rms
unmodulated
80% AM (1 kHz)
150 source impedance
Emission of radio frequency interference
Interference emission of electromagnetic fields according to EN 55016.
Table 14- 5 Interference emission of electromagnetic fields
Frequency
Interference emission
Measuring distance
30 MHz to 230 MHz
<40 dB (µV/m) Q
10 m
230 MHz to 1000 MHz
<47 dB (µV/m) Q
10 m
1 GHz to 3 GHz
<76 dB (µV/m) P
3 m
3 GHz to 6 GHz
<80 dB (µV/m) P
3 m
Interference emission via the AC power supply according to EN 55016.
Table 14- 6 Interference emission via the AC power supply
Frequency
Interference emission
0.15 MHz to 0.5 MHz < 79 dB (µV/m)Q
< 66 dB (µV/m) M
0.5 MHz to 30 MHz < 73 dB (µV/m)Q
< 60 dB (µV/m) M