Glossary
S7-1500 Automation System
System Manual, 01/2013, A5E03461182-01
201
GSD file
As a Generic Station Description, this file contains all properties of a PROFINET device that
are necessary for its configuration in XML format.
I/O modules
All modules that can be operated with a CPU or an interface module.
Identification data
Information that is saved in modules, and that supports the user in reviewing the system
configuration and locating hardware changes.
Interface module
Module in the distributed I/O system. The interface module connects the distributed I/O
system to the CPU (IO controller) via a fieldbus, and prepares the data for and from
I/O modules.
Isolated modules
In the case of isolated input/output modules, the reference potentials of the control and load
circuits are galvanically isolated, e.g. by means of optical isolators, relays or transformers.
Input/output circuits can be connected to common potential.
Load current supply
Supply of the input/output circuits of the modules, sensors and actuators.
MAC address
globally unique device identifier, which is assigned to each PROFINET device in the factory.
The 6 bytes of the address consist of a 3-byte manufacturer ID and a 3-byte device ID (serial
number). The MAC address is usually clearly legible on the device.
Nodes
Device that can send, receive or amplify data via the bus, e.g., I/O device via PROFINET IO.
Non-isolated modules
In the case of non-isolated input and output modules, the reference potentials of the control
and load circuits are electrically connected.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-1500 Automation System and is the answer not in the manual?

Siemens SIMATIC S7-1500 Automation System Specifications

General IconGeneral
SeriesSIMATIC S7-1500
ProgrammingTIA Portal (Totally Integrated Automation Portal)
Protection ClassIP20
CPUVarious models available (e.g., CPU 1511-1 PN, CPU 1518-4 PN/DP)
Controller TypeModular Controller
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
Communication InterfacesPROFINET, PROFIBUS, Ethernet, OPC UA
Digital InputsVaries by model and expansion modules
Digital OutputsVaries by model and expansion modules
Analog InputsVaries by model and expansion modules
Analog OutputsVaries by model and expansion modules
Backplane BusHigh-speed backplane bus for fast communication between modules
RedundancySupported with specific models and configurations
SafetyIntegrated safety functions available
ScalabilityHighly scalable with modular expansion
Operating Temperature0°C to 60°C

Related product manuals