EasyManuals Logo

Siemens SINAMICS G120C Function Manual

Siemens SINAMICS G120C
450 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #446 background imageLoading...
Page #446 background image
Safety relay, 70, 87
SAM (Safe Acceleration Monitor), 175, 182, 242
active, 317
SBC (Safe Brake Control), 34
Acceptance test, 392, 393
Requested, 233, 317
SBR (Safe Brake Ramp), 175, 240, 254, 260, 261
active, 317
SDI (Safe Direction), 42
Acceptance test, 404, 405, 406
active, 317
Delay time, 195
deselect, 317
Discrepancy, 288
Fault response, 290
select, 282
Switch off the motor, 283
Switch on motor, 285
Tolerance, 195
Self-test, 131, 134, 164, 165
Self-test (forced checking procedure), 147, 149
Serial number, 415
Series commissioning, 208, 211
Service personnel, 15
Setpoint speed limit, 258
Shared Device, 49, 204
Signals, 317
SIL (Safety Integrity Level), 370
SIMATIC ET 200pro FC‑2, 22, 24, 58
SIMATIC S7 block, 57
SINAMICS G110M, 22, 24
SINAMICS G120
CU230P-2, 22, 24
CU240B-2, 22, 24
CU240E-2, 22, 24
CU250S-2, 22, 24
SINAMICS G120C, 22, 24
SINAMICS G120D
CU240D-2, 22, 24
CU250D-2, 22, 24
SIZER, 438
SLS (Safely Limited Speed), 39, 253
Acceptance test, 395, 396, 397
active, 317
Braking ramp monitoring, 186
Delay time, 187
deselect, 254, 317
Discrepancy, 268
Fault response, 270
Level, 260
Level active, 262, 317
Monitoring mode, 253
Monitoring threshold, 261
Response, 184, 185
select, 254, 256, 258
Select level, 262, 317
Setpoint speed limit, 184, 185
Speed monitoring, 186
Standstill monitoring, 264
Switch off the motor, 264
Switch on motor, 266
Switching monitoring threshold, 260
Switching over speed monitoring, 261, 263
Speed monitoring, 294
Speed ratio, 151, 153
Spindle drive, 41
SS1 (Safe Stop 1), 36
Acceptance test, 387, 388, 390, 391
active, 317
Delay time, 175, 176, 178, 179, 180, 181, 182
Delay time for SBR, 175
deselect, 317
Discrepancy, 246, 249
Fault response, 251
Monitoring mode, 175
Monitoring time, 177, 178
Reference speed, 177, 178
Reference speed (reference velocity), 178
Reference velocity (reference speed), 178
select, 175, 238, 240, 242
Shutdown speed, 175, 176, 177, 179, 180, 181,
182
Speed tolerance, 180, 181
Standstill monitoring, 175, 176, 177, 240, 242
Switch off the motor, 244
Tolerance, 175, 182
Zero speed detection, 179
SSM (Safe Speed Monitoring), 44
Acceptance test, 399, 400
Fault response, 297
Feedback signal active, 273, 317
Filter, 191
Hysteresis, 190
Speed limit, 190
Switch off the motor, 274
Switch on motor, 278
Time response, 273
Standard acknowledgment, 301, 318
STARTER
Download, 104
Status F-DI via PROFIsafe, 117
Status word 1, 52, 53
Status word 5, 54
Index
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
446 Function Manual, 01/2017, FW V4.7 SP6, A5E34261271B AD

Table of Contents

Other manuals for Siemens SINAMICS G120C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120C and is the answer not in the manual?

Siemens SINAMICS G120C Specifications

General IconGeneral
Communication InterfacesPROFINET, PROFIBUS, USS, Modbus RTU
Protection ClassIP20
Ambient Temperature-10°C to +50°C
Storage Temperature-40°C to +70°C
Power Range0.55 kW to 132 kW
Voltage Range380 V to 480 V
Output Voltage0 V to Supply Voltage
Frequency Range0 Hz to rated output frequency
Control ModesVector control with encoder
ProtectionOverload, overvoltage, undervoltage, short circuit, ground fault
Relative Humidity5% to 95%, non-condensing
AltitudeUp to 2000 m without derating

Related product manuals