Power components on the motor side
6.1 Motor reactors
SINAMICS S110
126 Manual, 07/2015, 6SL3097-4AC10-0BP5
6.1.5
Electrical connection
Note
Approved cables for UL applications
Use only 75° C copper cables.
Table 6- 2 Securing the connection cables to the motor reactor
Frame
size
Terminal connection
PE connection
Max. cross-section
that can be con-
nected
Tightening torque
Fastening
Tightening torque
FSA
4 mm
2
0.6 … 0.8 Nm
M4 screw
3 Nm
FSB
10 mm
2
1.5 … 1.8 Nm
M5 screw
5 Nm
FSC
16 mm
2
2.0 … 4.0 Nm
M5 screw
5 Nm
FSD
35 mm²
2.5 … 4.5 Nm
M6 screw
8 Nm
FSE
70 mm²
8 … 10 Nm
M8 screw
10 Nm