CU305 Control Units
7.3 Interface description
SINAMICS S110
132 Manual, 07/2015, 6SL3097-4AC10-0BP5
Note
Function equipotential bonding for distributed DRIVE-CLiQ nodes
Integrate all of the components that are connected via
DRIVE-CLiQ into the function
equipotential bonding concept. The connection should be preferably established by mounting
on metallic bright machine and plant components that are connected with one another using
an equipotential bonding conductor.
vely, you can establish equipotential bonding using a conductor (min. 6 mm²), which
as far as possible, is routed parallel to the DRIVE
-CLiQ cable.
This applies to all distributed DRIVE
-CLiQ nodes such as DME20, SME2x, SME12x, etc.
Interface description
7.3.1
General interface overview
Table 7- 2 Interface overview classified according to terminal
Fail-safe digital inputs/outputs
Digital inputs/outputs, analog input
Digital inputs, temperature sensor input
Encoder interface (HTL/TTL/SSI)