Blocksize Power Modules (PM240-2)
4.6 Technical data
SINAMICS S110
100 Manual, 07/2015, 6SL3097-4AC10-0BP5
4.6.3
400 V Power Modules
Table 4- 21 Technical data of the PM240-2, FSA (400 V) (1/2)
Line voltage 3-phase 380480 V AC ± 10%
Internal
Article No.
without integrated line filter
with integrated line filter
6SL3210
1PE11-8UL1
1PE11-8AL1
6SL3210
1PE12-3UL1
1PE12-3AL1
6SL3210
1PE13-2UL1
1PE13-2AL1
6SL3210
1PE14-3UL1
1PE14-3AL1
Output current
Rated current I
n
Base-load current I
H
for S6 operation (40%) l
s6
Peak current l
max
A
A
A
A
1.7
1.3
2.0
2.6
2.2
1.7
2.5
3.4
3.1
2.2
3.5
4.7
4.1
3.1
4.5
6.2
Unit rating
1)
on basis of I
n
on basis of I
H
kW
kW
0.55
0.37
0.75
0.55
1.1
0.75
1.5
1.1
Rated pulse frequency
Max. Pulse frequency
kHz
kHz
4
16
4
16
4
16
4
16
Power loss
kW
0.04
0.04
0.04
0.07
Cooling air requirement
l/s
5
5
5
5
Sound pressure level LpA (1 m)
dB
49.2
49.2
49.2
49.2
24 V DC supply
for the Control Unit
A
1.0
1.0
1.0
1.0
Rated input current
2)
A
2.3
2.9
4.1
5.5
Resistance value
of the external
braking resistor
Ω ≥ 370 ≥ 370 ≥ 370 ≥ 370
Max. Cable length
to the braking resistor
m
15
15
15
15
Line supply connection
L1, L2, L3,
PE
Screw-type terminals
Cross head M2.5
Conductor cross section: 1.5 … 2.5 mm
2
Tightening torque: 0.5 Nm
Motor connection U2, V2, W2
DC-link connection, connection for
braking resistor
DCP/R1, DCN, R2
Max. Motor cable length
3)
shielded / unshielded
m
50 / 100
Degree of protection
IP20
Weight
Without line filter
With line filter
kg
kg
1.4
1.5
1.4
1.5
1.4
1.5
1.4
1.5
1)
Rated output of a typical standard induction motor at 400 V.
2)
The input current depends on the motor load and line impedance. The input currents apply for a load with the type rating
(based on I
rated
) for a line impedance corresponding to u
k
= 1%.
3)
To observe the limit values of EN 61800-3 category C2, for Power Modules PM240-2 with integrated line filter 50 m
(shielded) is the max. motor cable length. A cable length up to 150 m is possible for C2 if you use an unfiltered Power