Mounting
Note
Compliance with the EMC requirements
To meet the EMC requirements, make sure the contact surface of the heat sink is free of any
paint.
Installation steps
1. Make an installation cutout and drill holes for the Power Module and the mounting frame
according to the drilling pattern.
2. Fasten the mounting frame to the outer wall of the cabinet. Tighten the 2 screws finger-
tight.
3. Attach the seal to the inner side of the cabinet.
4. Fasten the Power Module. Tighten the screws finger-tight.
5. Tighten all screws with a torque of 3.5 Nm.