Supplementary system components and encoder system integration
8.2 Sensor Module Cabinet-Mounted SMC10
SINAMICS S110
Manual, 07/2015, 6SL3097-4AC10-0BP5
173
8.2.3.2
X500 DRIVE-CLiQ interface
Table 8- 3 X500: DRIVE-CLiQ interface
Pin
Signal name
Technical data
1
TXP
Transmit data +
2
TXN
Transmit data -
3
RXP
Receive data +
4 Reserved, do not use
5
Reserved, do not use
6
RXN
Receive data -
7
Reserved, do not use
8
Reserved, do not use
A
Reserved, do not use
B
M (0 V)
Electronics ground
Connector
type
DRIVE-CLiQ socket
The blanking cover for the DRIVE
-CLiQ port is included in the scope of delivery.
Blanking covers (50 x) Article No:: 6SL3066-4CA00-0AA0