Supplementary system components and encoder system integration
8.2 Sensor Module Cabinet-Mounted SMC10
SINAMICS S110
176 Manual, 07/2015, 6SL3097-4AC10-0BP5
Table 8- 6 Meaning of the LED on the Sensor Module Cabinet-Mounted SMC10
RDY
READY
- Off The electronics power supply is missing or outside the per-
missible tolerance range.
–
Green Continuous
light
The component is ready for operation. Cyclic DRIVE-CLiQ
communication is taking place.
–
Orange Continuous
DRIVE-CLiQ communication is being established. –
Red Continuous
light
This component has at least one fault.
The LED is activated irrespective of whether the corre-
sponding messages have been reconfigured.
Remove and
acknowledge the fault.
Green/
red
Flashing
Firmware is being downloaded. –
Flashing
Firmware download is complete. The system waits for
Carry out a POWER
Green/
orange
or
Red/
Flashing
light
Component recognition via LED is activated
1)
.
Both options depend on the LED status when component
recognition is activated.
–
1)
See SINAMICS S110 List Manual for the parameters to activate component recognition via LED
Cause and rectification of faults
The following documents contain information about the cause of faults and how they can be
rectified:
● SINAMICS S110, Function Manual
● SINAMICS S110, List Manual