Mounting
The line reactors for Power Modules PM240-2 of frame sizes FSA to FSC are designed for
installation in a cabinet. The line reactor is installed on the mounting surface next to the
Power Module. The line reactor is connected to the line supply through terminals.
Table 3- 13 Connecting the line reactor for the PM240-2 on the mounting surface
Frame size
Fastening
Tightening torque
FSA
4 x M5 screws
4 x M5 nuts
4 x M5 washers
6 Nm
FSB
FSC 4 x M6 screws
4 x M6 nuts
4 x M6 washers
10 Nm