Table 7- 26 Technical data for CU305 PN/DP/CAN
Unit
Value
Electronics power supply
Voltage
Current consumption (without DRIVE-CLiQ
and digital outputs)
Power loss
V
DC
A
DC
W
24 (20.4 … 28.8)
0.8
< 20
Measuring system power supply
Voltage
Current
V
DC
A
DC
TTL: 5 V (with or without remote sense)
HTL: V
DC
- 1 V
0.35
PE/ground connection On the housing with M4 screw
Tightening torque: 3 Nm
Response time The response time of digital inputs/outputs depends on the evaluation (see
SINAMICS S110 List Manual, Function Diagrams).
Weight
kg
0.95