EasyManua.ls Logo

Siemens SINAMICS S110 - Behavior of the Leds in the Operating State

Siemens SINAMICS S110
268 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CU305 Control Units
7.5 Meaning of LEDs
SINAMICS S110
Manual, 07/2015, 6SL3097-4AC10-0BP5
159
LED
Status
Comment
RDY
COM
OUT>5V
MOD
Red 0.5 Hz Red 0.5 Hz OFF OFF Firmware update
complete, waiting for
POWER ON
-
Red 2 Hz Red OFF OFF Firmware check
(CRC error)
CRC is incorrect.
Red 2 Hz Red 2 Hz OFF OFF Firmware or memory
card incompatible
Check the firmware version or
memory card.
7.5.2
Behavior of the LEDs in the operating state
Table 7- 25 Control Unit CU305 - description of the LEDs in the operating state
LED
Color
Status
Description/cause
Remedy
RDY
(READY)
- Off Electronics power supply is missing or outside
permissible tolerance range.
Check the power sup-
ply
Green Continuous light The unit is ready for operation.
Cyclic DRIVE-CLiQ communication is in pro-
gress.
-
Flashing light
0.5 Hz
Commissioning/reset -
Flashing light 2
Hz
Writing to the memory card. -
Red 2 Hz
flashing light
General errors Check parameter
assign-
ment/configuration.
Red/green 0.5 Hz
flashing light
The Control Unit is ready for operation, but there
are no software licenses.
Install the missing
licenses.
Orange 0.5 Hz
flashing light
Updating the firmware of the DRIVE-CLiQ com-
ponents.
-
2 Hz
flashing light
DRIVE-CLiQ component firmware update com-
pleted. Waiting for POWER ON of the corre-
sponding component.
Switch on the compo-
nent.
Green/
Orange
or
Red/
Orange
2 Hz
flashing light
Recognition of components via LED is activat-
ed
1)
.
Note:
Both options depend on the LED status when
activated.
-

Table of Contents

Other manuals for Siemens SINAMICS S110