Supplementary system components and encoder system integration
8.2 Sensor Module Cabinet-Mounted SMC10
SINAMICS S110
Manual, 07/2015, 6SL3097-4AC10-0BP5
179
Table 8- 7 Technical data
Voltage
Current (without encoder system)
Current (with encoder system)
Power loss
V
DC
A
DC
A
DC
W
24 (20.4 … 28.8)
≤ 0.20
≤ 0.35
≤ 10
Transformation ratio of the resolver (ü)
Excitation voltage on the SMC10 when ü=0.5
Amplitude monitoring threshold (secondary
V
rms
V
rms
0.5
4.1
1
Excitation voltage (cannot be parameterized)
rms
Excitation frequency (synchronized to the current
kHz 5 to 16
At the housing with M4/1.8 Nm screw
Max. Encoder cable length
Table 8- 8 Max. frequency that can be evaluated (speed)
Max. Speed, resolver/motor
The ratio between the ohmic resistance R and the inductance L (the primary winding of the
resolver) determines whether the resolver can be evaluated with the SMC10. See the
following diagram: