CU305 Control Units
7.3 Interface description
SINAMICS S110
Manual, 07/2015, 6SL3097-4AC10-0BP5
147
Note
An additional external electronics power supply via terminal X124 is required in two cases:
if digital outputs are used DO 8 to DO 11
If the CU305 is to remain functional after the Power Module has been switched off
X130 fail-safe digital inputs
Table 7- 17 X130 fail-safe digital inputs
1 DI 16 F-DI 0 Voltage: -3 … 30 V DC
Input characteristics in accordance with
IEC61131-2, type 1
Typical current consumption: 6 mA at 24 V DC
Electrical isolation: The reference potential is
terminal M1
Permissible level (incl. ripple)
High level: 15 … 30 V
F-DI 1
6 DI 19-
7 24 V1 Additional external power supply for intercon-
necting DI 16 / DI 18 with ground M1
See also Connection example, CU305 with
safety function (Page 154)
8 M1 Reference potential for the fail-safe digital
Type: Spring-loaded terminal (Page 263)
Max. cross section that can be connected: 1.5 mm
2
1)
DI: Digital input, F-DI: Fail-safe digital input
The maximum cable length that can be connected is 30 m.
An F-DI consists of two digital inputs. The cathode of the optocoupler is additionally
connected to one of these.
ut is interpreted as "low."
Note
If M1 is connected to M (X124 or X132), the system is no longer electrically isolated.