Blocksize Power Modules (PM240-2)
4.3 Interface description
SINAMICS S110
80 Manual, 07/2015, 6SL3097-4AC10-0BP5
4.3.5
Braking resistor and DC link connection
Power Modules PM240-2: FSA, FSB, and FSC
Table 4- 6 Removable braking resistor and DC link connector
Terminal
Signal name
Technical data
1
DCN
DC link negative
2 DCP/R1 DC link positive and positive
connection for braking resis-
tor
3 R2 Negative connection for the
braking resistor
Power Modules PM240-2: FSD
Table 4- 7 DC link terminals
Terminal
Signal name
Technical data
1
DCN
DC link negative
2 DCP DC link positive
Table 4- 8 Braking resistance terminals
Terminal
Signal name
Technical data
1
F3
currently not assigned
2 R2 negative connection for the
braking resistor
3 R1 positive connection for brak-
ing resistor
Power Modules PM240-2: FSE
Table 4- 9 DC link terminals
Terminal
Signal name
Technical data
1
DCN
DC link negative
2 DCP DC link positive