Service and maintenance
11.2 Service and maintenance for components, Blocksize format
SINAMICS S110
Manual, 07/2015, 6SL3097-4AC10-0BP5
247
4. Remove the fan module from the Power Module as shown in the diagram.
Figure 11-1 Pull out the fan on PM240-2 FSA to FSC
5. Install the new fan module in the inverse sequence.
6. Reconnect all cable connectors.
Procedure for replacing the fan module FSD and FSE
1. Switch-off the inverter, and wait 5 minutes until the DC link capacitors have been
discharged.
2. Pull the fan module out of the Power Module. No tools are required for this. Pulling out
the fan module also disconnects the electrical connections.
Figure 11-2 Removing the fan from PM240-2 FSD and FSE
3. Install the new fan module in the inverse sequence.