System overview
2.4 System data
SINAMICS S110
30 Manual, 07/2015, 6SL3097-4AC10-0BP5
Chemically active substances
Long-term storage in the transport packaging
Class 1C2 according to EN 60721-3-1
Transport in the transport packaging
Class 2C2 according to EN 60721-3-2
Operation Class 3C2 for the drive system, class 3C3 for the Power Modules acc.
Biological environmental conditions
Storage in the transport packaging
Class 1B1 according to EN 60721-3-1
Transport in the transport packaging
Class 2B1 according to EN 60721-3-2
Class 3B1 according to EN 60721-3-3
Long-term storage in the transport packaging
Class 1M2 in accordance with EN 60721-3-1
Transport in the transport packaging
Class 2M3 in accordance with EN 60721-3-2
Class 3M2 according to EN 60721-3-3
Long-term storage in the transport packaging
Class 1M2 in accordance with EN 60721-3-1
Transport in the transport packaging
Class 2M3 in accordance with EN 60721-3-2
Class 3M2 according to EN 60721-3-3
Climatic environmental conditions
Long-term storage in the transport packaging Class 1K4 according to EN 60721-3-1
Temperature: -25°C ... +55°C
Transport in the transport packaging Class 2K4 according to EN 60721-3-2
Temperature: -40°C ... +70°C
Operation Temperature: 0 … +40°C
Relative humidity: 5 … 95 % (better than 3K3)
Oil mist, salt mist, ice formation, condensation, dripping water, spraying
water, splashing water and water jets are not permitted
Table 2- 3 Certificates
Declarations of conformity
CE (Low Voltage, EMC, and Machinery Directives)
Approvals cULus acc. to UL 61800-5-1
CSA only with external surge protection devices
C-Tick
SEMI F47
KCC only with internal or external line filters
WEEE (Waste Electrical & Electronic Equipment)
RoHS