Commissioning Manual
10 01/2017
17.8.2 General signals from NCK .................................................................................................................. 443
17.8.3 Signals at fast inputs and outputs ....................................................................................................... 443
17.8.4 Signals from fast inputs and outputs ................................................................................................... 444
17.9 Channel signals .................................................................................................................................. 445
17.9.1 Signals to NC channel ......................................................................................................................... 445
17.9.2 Signals from NC channel .................................................................................................................... 447
17.10 Axis/spindle signals ............................................................................................................................. 450
17.10.1 Transferred M and S functions, axis specific ....................................................................................... 450
17.10.2 Signals to axis/spindle ......................................................................................................................... 450
17.10.3 Signals from axis/spindle .................................................................................................................... 453
17.11 PLC machine data............................................................................................................................... 455
17.11.1 INT values (MD 14510 USER_DATA_INT) ......................................................................................... 455
17.11.2 HEX values (MD 14512 USER_DATA_HEX) ...................................................................................... 455
17.11.3 FLOAT values (MD 14514 USER_DATA_FLOAT) .............................................................................. 455
17.11.4 User alarm: Configuring (MD 14516 USER_DATA_PLC_ALARM) ..................................................... 456
17.12 Signals, synchronized actions ............................................................................................................. 456
17.12.1 Signals, synchronized actions to channel ........................................................................................... 456
17.12.2 Signals, synchronized actions from channel ....................................................................................... 456
17.12.3 Reading and writing PLC variables ..................................................................................................... 456
17.13 Axis actual values and distance-to-go ................................................................................................. 457
17.14 Maintenance scheduler: User interface ............................................................................................... 457
17.14.1 Initial (start) data ................................................................................................................................. 457
17.14.2 Actual data .......................................................................................................................................... 457
17.15 User interface for ctrl energy ............................................................................................................... 458
A Appendix ............................................................................................................................................................ 459
A.1 Operation and display ......................................................................................................................... 459
A.1.1 Operating the SINAMICS V70 Basic Operator Panel (BOP) ............................................................... 459
A.1.1.1 BOP overview ..................................................................................................................................... 459
A.1.1.2 Parameter structure ............................................................................................................................ 463
A.1.1.3 Actual status display ........................................................................................................................... 464
A.1.1.4 Basic operations ................................................................................................................................. 464
A.1.1.5 Auxiliary functions ............................................................................................................................... 466
A.1.2 Operating the SINAMICS V60 Basic Operator Panel (BOP) ............................................................... 471
A.1.2.1 BOP overview ..................................................................................................................................... 471
A.1.2.2 Main menu .......................................................................................................................................... 471
A.1.2.3 Function menu .................................................................................................................................... 473
A.1.2.4 Parameter setting menu ...................................................................................................................... 475
A.1.2.5 Data display menu .............................................................................................................................. 476
A.1.2.6 Setpoints from the PPU ....................................................................................................................... 476
A.2 Replacing the fan for the V70 drive ..................................................................................................... 477
A.3 Replacing the fan for the 1PH1 motor ................................................................................................. 480
A.4 Assembling the power cable for the 1PH1 motor ................................................................................ 480
A.5 Assembling the line supply terminal for the drive ................................................................................ 483
A.6 Cutting reserved holes in the MCP ..................................................................................................... 483
A.7 Customizing pre-defined labeling strips for keys of the MCP .............................................................. 484
A.8 Diagnostics ......................................................................................................................................... 485
A.8.1 SINUMERIK 808D/SINUMERIK 808D ADVANCED alarms ................................................................ 485
A.8.2 SINAMICS V70 faults and alarms ....................................................................................................... 486
A.8.2.1 General information about faults and alarms ...................................................................................... 486
A.8.2.2 List of faults and alarms ...................................................................................................................... 487
A.8.3 SINAMICS V60 faults and alarms ....................................................................................................... 499
A.8.3.1 Overview ............................................................................................................................................. 499
A.8.3.2 Common faults and alarms ................................................................................................................. 499
A.8.3.3 Errors during drive self-test ................................................................................................................. 502
A.8.3.4 Other faults ......................................................................................................................................... 502
A.9 AMM communication tool .................................................................................................................... 503
A.9.1 File management and transfer ............................................................................................................ 503
A.9.2 Remote control .................................................................................................................................... 505
A.9.2.1 Configuring the remote control ............................................................................................................ 505