114 01/2017
Main circuit wiring for SINAMICS V70 FSD
Note
For more information about the wiring of the external braking resistor, see Section "
Connecting an external braking resistor
(Page
121)".
Note
Filter
A line filter is required so that the system can pass the CE certification (radiated emission test or conducted emission test
).
Type E combination motor controller/circuit breaker
You can install a Type E combination motor controller or circuit breaker to protect the system.
For more information about the article numbers of Siemens recommended filters and Type E combination motor
controllers/circuit breakers, see Sections "
Line filters (Page 31)" and "
Fuse/Type E combination motor controllers and circuit
breakers
(Page 30)".
4.4.4
Connecting the 24 V power supply/STO - X6
Control circuit interfaces - drive side
Type
Illustration
Safe Torque Off (STO) interfaces
Control power input interfaces
1)
Maximum connectable cross-section: 1.5 mm
2
1)
Maximum current consumption values without a brake power supply and with a brake power supply are respectively 1 A
and 3 A.