Fuse/Type E combination motor controllers and circuit breakers
The fuse/Type E combination motor controller or circuit breaker is used to protect the control system.
SINAMICS V70
Standard fuse
Type E combination motor controller (for all
feed drives and spindle drive FSB)
Circuit breakers (for spindle drives FSC and
FSD only)
Frame size
Article number
Rated current
(A)
Article number
Rated cur-
rent (A)
Rated volt-
age (VAC)
Article number
Feed
drive
FSA
6SL3210-5DE12-4UA0
6
3NA3801-6
2.8 to 4
690
3RV2021-1EA10
6SL3210-5DE13-5UA0
10
3NA3803-6
3.5 to 5
690
3RV2021-1FA10
FSB
6SL3210-5DE16-0UA0
10
3NA3803-6
5.5 to 8
690
3RV2021-1HA10
6SL3210-5DE17-8UA0
16
3NA3805-6
11 to 16
690
3RV2021-4AA10
6SL3210-5DE21-0UA0
16
3NA3805-6
14 to 20 690 3RV2021-4BA10
FSC 6SL3210-5DE21-4UA0 20 3NA3807-6
6SL3210-5DE21-8UA0
25
3NA3810-6
20 to 25 690 3RV2021-4DA10
Spin-
dle
drive
FSB
6SL3210-5DE21-1UA0
25
3NA3810
FSC 6SL3210-5DE21-3UA0 32 3NA3812 30 690 3VL1103-
1KM30-0AA0
6SL3210-5DE22-0UA0 40 3NA3817 40 690 3VL1104-
1KM30-0AA0
FSD 6SL3210-5DE23-0UA0 63 3NA3822 60 600 3VL1106-
1KM30-0AA0
6SL3210-5DE24-0UA0 80 3NA3824 80 600 3VL1108-
1KM30-0AA0
Note: The above types of fuses and Type E combination motor controllers are compliant with the CE standard.
Braking resistors
A braking resistor is used for the SINAMICS V70 drive. For the feed drive, when the internal braking resistor cannot meet the
braking requirements, an external braking resistor can be used to "dump" the regenerative energy produced by the motor,
thus giving greatly improved braking and deceleration capabilities. For the spindle drive, an external braking resistor must be
configured. Select a standard braking resistor according to the table below:
Drive frame
size
Braking resistor
Illustration
Resistance (Ω)
Max. power (kW)
Rated power (W)
Max. energy (kJ)
FSA
160
4
100
8
FSB
70
9.1
229
18.3
FSC
27
23.7
1185
189.6
FSD
18
37.4
1870
299.2
Shielding plate
To achieve EMC-compliant installation of the drive, use shielding plates to connect the cable shields. The shielding plate for
V70 spindle drive FSD is provided as an option. While for V70 drives of other frame sizes, the shielding plates are provided
at delivery.
Drive variant
Article number
Component
Quantity
V70 FSD 6SL3266-1ED00-0VA0
Shielding plate
2
M6 screws
4

Table of Contents

Other manuals for Siemens SINUMERIK 808D ADVANCED

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 808D ADVANCED and is the answer not in the manual?

Siemens SINUMERIK 808D ADVANCED Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 808D ADVANCED
CategoryControl Unit
LanguageEnglish

Related product manuals