3004
Reading: data from NCK variable x (data type of the variables: 1 to 4 bytes)
1)
0: no error; 3: illegal access to object; 5: invalid address; 10: object does not exist
17.3
PI Service
17.3.1
PI service: Job
DB1200
PI service [r/w]
PLC → NCK interface
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
4000
Start
4001
PI index
4002
4003
4004
PI parameter 1
4006
PI parameter 2
4008 PI parameter 3
4010
PI parameter 4
4012
PI parameter 5
4014
PI parameter 6
4016
PI parameter 7
4018
PI parameter 8
4020
PI parameter 9
4022
PI parameter 10
17.3.2
PI service: Result
DB1200
Reading / writing NC data [r]
NCK → PLC interface
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
5000 Error in job Job com-
pleted
5001
5002
17.4
Retentive data area
DB1400
Retentive data [r/w]
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
User data
0
User data
1
User data
2
...
...
32
...

Table of Contents

Other manuals for Siemens SINUMERIK 808D ADVANCED

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 808D ADVANCED and is the answer not in the manual?

Siemens SINUMERIK 808D ADVANCED Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 808D ADVANCED
CategoryControl Unit
LanguageEnglish

Related product manuals