Initial system setup
5.1
System startup menu
The control system carries out a normal startup by default after power
-on. When necessary, you can press this
key on the PPU once the message "Press the SELECT key to enter set
-up menu" appears while the system
boots to select other startup options via the following menu:
â‘ 
The system carries out a normal startup.
â‘¡
The system loads the user data saved through the following oper
ations from the system CF card:
+ →
â‘¢
The system loads the default NC data and sett
ings, and deletes the retentive data on the PLC.
â‘£
The PLC is stopped.
⑤
The system resets the PLC and loads the default PLC program.
â‘¥
The system loads the default HMI settings.
⑦
The system installs an update on the system CF card from the USB fl
ash drive.
Note: The above menu options â‘¢ to â‘¥ are only visible if the manufacturer password is set before last power-off.

Table of Contents

Other manuals for Siemens SINUMERIK 808D ADVANCED

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 808D ADVANCED and is the answer not in the manual?

Siemens SINUMERIK 808D ADVANCED Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 808D ADVANCED
CategoryControl Unit
LanguageEnglish

Related product manuals