Configuration
3.3 Connection overview
Manual
116 Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
1. Connectors:
6ES7972-0BA41-0XA0; cable outlet 35
0
, without PC socket connector
6ES7972-0BB41-0XA0; cable outlet 35
0
, with PC socket connector
6ES7972-0BA12-0XA0; cable outlet 90
0
, without PG socket connector
6ES7972-0BB12-0XA0; cable outlet 90
0
, with PG socket connector
Cables:
6XV1830-0EH10; by the meter, non-trailable
6XV1830-3EH10; by the meter, trailable
2. Connectors:
6GK1500-0EA02; cable outlet 180
0
, without PG-socket connector
Cables:
6XV1830-0EH10; by the meter, non-trailable
6XV1830-3EH10; by the meter, trailable
3. Connectors:
6ES7972-0BB41-0XA0; cable outlet 35
0
, with PC socket connector
6ES7972-0BB12-0XA0; cable outlet 90
0
, with PG socket connector
Cables:
6XV1830-0EH10; by the meter, non-trailable
6XV1830-3EH10; by the meter, trailable
4. The cable is included in the scope of supply
for an overview of the standard PC interfaces see Section
"PCU 50.3" (Page 114) as well
as:
References:
/BH/ Operator components Manual, Component PCU 50.3
5. Cables: 6FX8002-2CP00-1A0
6. The detailed connection overview for ADI4 is given in:
References:
/ADI4/ analog drive interface for 4 axes, connection overview
7. Connection with the help of Fast Connect (insulation displacement method) see:
References:
SIMATIC Manual: Diagnostic repeater for PROFIBUS DP
8. Can be parameterized alternatively as MPI or PROFIBUS interface.
Only the PLC can access this PROFIBUS interface. No drives and no NCK I/Os can be
operated via this PROFIBUS line.