PLC commissioning
6.3 Creating a SIMATIC S7 project
Manual
164 Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
6.3.4 Inserting the 840Di sl Rack
The 840Di sl rack contains the already partially preconfigured components:
● SINUMERIK 840Di sl PLC
Default designation: PLC 317-2DP 2AJ10
● MPI/DP interface
Default designation: MPI/DP
● PROFIBUS DP interface
Default designation: DP
● SINUMERIK 840Di sl NC
Default designation: NCK 840D sl
● SINUMERIK CP for Industrial Ethernet TCP/IP
Default designation: CP 840D sl
Inserting the 840Di sl Rack
The 840Di sl Rack is located in the hardware catalog under:
Profile: Standard
SIMATIC 300 > SINUMERIK > 840Di sl > 840Di sl
Right-click to select the 840Di sl Rack and drag it to the Station window, while holding down
the mouse button. When you release the mouse button, the 840Di sl Rack will be inserted in
the S7 project.
6HDUFK
3URILOH
+:FRQILJ>6,180(5,.FRQILJXUDWLRQ6,1'LVO@
6WDWLRQ(GLW,QVHUW7DUJHW9LHZ7RROV:LQGRZ+HOS
GHIDXOW
6,0$7,&
&
&3
&38
)0
,0
0(;7(16,21
*DWHZD\
36
5$&.
60
6,180(5,.
'LVO
'LVO
'LVO3/&'3$-
6,180(5,.'LVO
Figure 6-5 HW Config: SINUMERIK 840Di sl Rack